Applies to

DocuWare on-premises. 7.12.

What to check

For DocuWare 7.12, the queue administration utility is under Power Tools rather than the older Setup Components location. Using an older runbook can therefore send an administrator to the wrong executable.

Practical steps

  • Capture the failing Autoindex, Transfer, Request or deletion job and confirm the server is on 7.12.
  • Review the source procedure before stopping DocuWare services and IIS. Multi-server installations need coordinated work on each server.
  • Locate MessageBusAdministration under the DocuWare Power Tools directory and use the documented adapter selection, queue reset and restart sequence.

Confirm the result

Verify that the chosen job completes after services return. A queue reset affects shared processing, so retain the original failure logs and planned recovery steps.